Stratus Redundant Linux Release 2.0.0.0 Release Notes

These Release Notes (updated at 10:20 PM on 4/29/2021) are for Stratus Redundant Linux Release 2.0.0.0, which runs on ztC Edge systems. See the following sections:

New Features and Enhancements

The following features are new in Stratus Redundant Linux Release 2.0.0.0:

Bug Fixes

Bugs Fixed in ztC Edge Release 2.0.0.0

EV-48962: SMD logs unnecessary messages.

EV-48473: VM(s) will not start because axstore.db has a size of 0.

EV-48341: Windows VM crashes when last available network adapter is disabled.

EV-48304: Memory leaks.

EV-48191: System Manager does not start the AX-QEMU after it was shutdown due to CoreFT Fault Handler.

EV-47890: Modifying the MTU with the GUI on a system licensed for one node results in System Manager problems.

EV-47860: Guest AXs cannot communicate with each other if A-Links references were crossed.

EV-47802: System management state corrupted after power loss.

EV-47754: System management restart causes a false node reboot alert message.

EV-47673: Private branded customization lost during node replace.

EV-47611: Interrupting and restarting mirror copy can fail.

EV-47091: Importing FT VM onto HA system cannot start due to unlicensed feature.

CVE Fixes

For a list of the CVE fixes, see Fixed CVEs.

Important Considerations

Upgrading to Stratus Redundant Linux Release 2.0.0.0

To upgrade to the current release of Stratus Redundant Linux, review KB-9783 before following the instructions in Upgrading Stratus Redundant Linux Software Using an Upgrade Kit.

To determine the version of Stratus Redundant Linux running on a ztC Edge system, log on to the ztC Console for the system and check the system information in the masthead:

ocean.abc.com
IP: 123.109.50.34 | Asset ID: ze-12345
Version: n.n.n-nnn

If the software release is lower than Release 2.0.0.0, download the Stratus Redundant Linux 2.0.0.0 Upgrade Kit from the Downloads page at https://www.stratus.com/services-support/downloads/?tab=ztcedge and upgrade the software on the system as described in Upgrading Stratus Redundant Linux Software Using an Upgrade Kit.

Using Intel Active Management Technology (AMT) for Lights-Out Support

ztC Edge systems incorporate Intel Active Management Technology (AMT) lights-out support for remote power management, remote console, and remote media. For important information about AMT configuration and restrictions, see KB-8219.

Redeploying a ztC Edge System

Redeploying a ztC Edge system allows you to clear the network settings of the system to prepare it for deployment on a different network. If you need to move a system to a new network, redeploy and shut down the system before moving it, as described in Redeploying a ztC Edge System.

When you redeploy a system, note the following issues and workarounds:

Deploying ztC Edge Nodes at Separate Physical Sites

When you deploy a ztC Edge system, you must deploy both nodes at the same site and directly connect the A-links between the blue (A2) and yellow (A1) network ports of each node. If you want to set up a ztC Edge system in an ALSR configuration, where each node is located at a separate physical site for increased redundancy, contact your authorized Stratus service representative for assistance. Because of the geographic separation, an ALSR configuration requires careful planning of component placement and networking topologies.

Known Issues

Additional upgrade issues

When upgrading from version 1.3.0.0, an older version of Intel processor microcode may be loaded.

When upgrading to 2.0.0.0, one or more VMs may be lost. Refer to KB-9783 to upgrade to 2.0.0.0 safely.

To import a VMware VM, use operating system shutdown commands

When importing a VMware VM, you must shutdown the VM using operating system shutdown commands in addition to powering it off from the VMware console. If you shutdown the VM using only the VMware console, the import will fail.

P2V Conversion and V2V Conversion of Ubuntu 18.04 Guest Is Not Supported

Ubuntu 18.04 guests can be created directly or imported with no issues. However, P2V conversion and V2V conversion of Ubuntu 18.04 guest is not supported.

Mapping of Japanese Keyboards 106 and 109 For Console in IE10, IE11, or Firefox May Be Incorrect

The mapping of the Japanese keyboards 106 and 109 may be incorrect when using IE10, IE11, or Firefox to access the ztC Console. Use Chrome or remote connection software (VNC or RDP), instead.

Migrating a VM With Monitoring Set Causes "No response"

When monitoring on a VM is set for all three parameters (CPU, Memory, and Disk), and the VM is migrated to the other node, the Monitor tab displays No response from guest agent. It may take several minutes for the guest agent to reconnect.

VMs Reported as Broken Instead of Degraded When A-Link Is Offline

If an A-link cable or network is disconnected on one node, the state of a VM on that node may be reported as broken () in the ztC Console, even though the VM still has another active A-link connection. The availability of the VM is unaffected.

Ejected VCD Still Displayed in a Linux-based VM Console

If you use the ztC Console to eject a VCD from a VM running a Linux-based guest operating system, the VCD may still be displayed in the guest operating system. If needed, you can eject the VCD in the guest operating system to stop displaying the VCD.

Cannot Re-mount USB Media After Ejecting from Windows File Explorer in a VM

If you eject USB media from File Explorer in a Windows VM, you cannot re-mount the media without first physically disconnecting the media from the ztC Edge system.

VM Network Remains Offline After Using P2V/V2V to Migrate from a VMware Source and After Importing a Windows-based VM

If you use the P2V client (virt-p2v) to migrate a PM or VM from a source that is running VMware, the network driver might fail to install properly during the migration process, which leaves the VM network offline. If this happens, manually install the network driver in Device Manager. For instructions, see the Troubleshooting section of Migrating a Physical Machine or Virtual Machine to a System.

If you import a Windows-based VM with the Import/Restore Virtual Machine Wizard, the VirtIO network driver may fail to install properly the first time you start the VM, which leaves the VM network offline. If this happens, manually install the network driver in Device Manager. For instructions, see the Troubleshooting section of Importing an OVF File.

Ensure that Both Nodes Are Connected to the Network Before Creating a VM

Before creating a VM, always ensure that the network you assign to the VM has an active network connection in each node of the system. You can verify the state of the networks on the Networks page of the ztC Console.

If you add a VM while one of the paired network interfaces is offline, the VM will not start. To start the VM, connect an active network cable to the offline interface, wait a few seconds, and start the VM.

Ensure that Both Nodes Are Running Before Removing a VM

To avoid downtime, before removing a VM, always ensure that both nodes are in the running state and that neither node is in maintenance mode or in the process of synchronizing.

If you remove a VM while one node is shut down in maintenance mode, the operation may stall with the error, "There was a problem deleting vm-name." To correct the problem, you must restart the only running node.

Invalid VM Names Prevent Some VM Operations from Executing

The ztC Console may improperly validate VM names to ensure that they meet the software requirements. If you are creating, reprovisioning, or renaming a VM with an unsuitable name, the operation may fail to execute.

To avoid any problems with VM operations, ensure that your VM names meet the following requirements:

Some Browsers Unable to Connect a VNC When Using https

If you are connected to the ztC Console using an https URL in a Microsoft Internet Explorer or Mozilla® FireFox® browser, and you click Console after selecting a running VM from the Virtual Machines page, the message VNC: Unable to connect, retrying in n seconds may appear. To enable the VNC connection, click the https link to the VNC console page in the upper right-hand corner of the masthead, and continue with the appropriate procedure below (procedure in your browser may differ, depending on the version of your browser):

The VNC console appears.

Cannot Mount USB Media with exFAT File System

The Stratus Redundant Linux software on ztC Edge systems does not support the exFAT File system. If you need to mount a USB medium to import or export a VM, as described in Mounting a USB Device or Network-mounted Folder on the ztC Edge System, format the device with NTFS. (By default, most USB media are formatted with the FAT file system, which has a limited file size of 4 GB that may be too small for most VMs.)

Using USB 3.x Devices

You can attach only supported USB devices to a guest operating system. ztC systems support USB devices and provide USB ports, as follows:

Some USB devices claim to be 3.0 compatible, but are not. If you are using such a device, switch to another USB device that is 3.0 compatible.

Reboot Required when Changing Node IP Address or Netmask Network Settings

When you change the IP address or netmask settings of a node as described in Configuring IP Settings, both the old and new settings are in effect until you reboot the node. Having both settings active may cause routing or connection issues.

Documentation Updates

The following Help topics have been updated since translation:

Beginning in Release 2.0.0.0, Help is available in German, Japanese, Chinese, and Portuguese.

Accessing Stratus Knowledge Base Articles

The Stratus Customer Service Portal provides a searchable Knowledge Base with technical articles about all Stratus products, including ztC Edge systems and Stratus Redundant Linux software. In some cases, the Release Notes directly reference these Knowledge Base articles (for example, KB-nnnn). You can access the Customer Service Portal and the Knowledge Base articles by using your existing service portal credentials, or by creating a new user account, as follows.

To access the Knowledge Base

  1. Log on to the Stratus Customer Service Portal at https://support.stratus.com.

    If needed, create a new account as follows:

    1. Click Register Account.
    2. Enter your company email address and contact info, and click Register.

      Your company email address must include a domain name (for example, stratus.com) for a company that is a registered customer of Stratus.

    3. Click the link in the email that you receive from Stratus.
    4. Enter a new password and finish configuring your account.

    If you need assistance creating an account, contact your authorized Stratus service representative.

  2. In the service portal, click Knowledge Base in the left pane.
  3. In the Keyword Search box, enter keywords associated with the information you need, and then click Search.

    To search for an article by its KB-nnnn number, click Advanced Search. Next to Search by ID, type the article ID number (nnnn) and click Display.

Getting Help

If you have a technical question about ztC Edge systems, you can find the latest technical information and online documentation at the Downloads page at https://www.stratus.com/services-support/downloads/?tab=ztcedge. You can also search the Knowledge Base in the Stratus Customer Service Portal at https://support.stratus.com.

If you cannot resolve your questions with these online resources, and the system is covered by a service agreement, contact your authorized Stratus service representative. For information, see the ztC Edge Support page at https://www.stratus.com/services-support/customer-support/?tab=ztcedge.