Space Recommendations
To ensure that the installation site for a ztC Edge system provides a properly equipped, cooled, and sized environment, consider the following space recommendations for your site.
Space recommendations for nodes located on a table follow:
- At least 2 in. (5.08 cm) of space on the left and right sides of a node
- At least 3 in. (7.62 cm) of space on the top of a node
- At least 5 in. (12.7 cm) of space on the front and rear of a node
- At least 2 in. (5.08 cm) of space between nodes
Space recommendations for DIN rail-mounted nodes follow:
- At least 2 in. (5.08 cm) of space on the left and right sides of a node
- At least 5 in. (12.7 cm) of space on the top and bottom of a node
- At least 2 in. (5.08 cm) of space between nodes
Additional space recommendations follow:
- A node can be installed either horizontally (on a flat surface) or vertically (on a wall). If a node is installed vertically:
- For a ztC Edge 100i or 110i node, the surface with the Stratus logo should be facing up.
- For a ztC Edge 200i or 250i node, the surface with the ports should be facing down.
-
To prevent damaging the system’s cables, the bend radius for all cables should be at least 2 in. (5.08 cm).
-
Avoid installing any kind of heat-generating source below the node.
-
Avoid exceeding the operational environmental limits of the node.
- Each node should have at least 100 LFM (0.51 m/s) of airflow over the heatsink for optimal heat transfer.
In addition to the preceding recommendations, evaluate your site's specific installation needs. If you need further guidance, contact your authorized Stratus service representative.