Shutting Down a Physical Machine

Shut down a physical machine (PM), or node, to stop it from running when you need to service or replace the PM. Use the following procedures to shut down one and only one PM by using the ztC Edge Console or the power button on the PM.

Cautions:  
  1. Data loss will occur if you use the following procedures to shut down both PMs of a ztC Edge system configured with two nodes or the one PM of a system configured with one node. If you need to stop both PMs of a system configured with two nodes or the one PM of a system configured with one node, shut down the system (which also shuts down the virtual machines (VMs)), as described in Shutting Down the System.
  2. Do not use the -f (force) option with the halt, poweroff, or reboot command of the host operating system of a PM. Doing so causes guests that are active on the same PM to hang.
  3. A ztC Edge system configured with two nodes is not fault tolerant when you shut down a PM. For continuous uptime, bring an offline PM back into service as soon as possible.
Note: When you shut down a PM, standby power remains on for lights-out management unless you disconnect the power cord or AC mains power is lost.

To shut down a PM in the ztC Edge Console

To shut down a PM, you must place the PM into maintenance mode, which migrates any VMs running on that PM to the remaining PM (if it exists). On a system with two nodes, the VMs continue to run during this process, which takes a minute or two.

  1. Determine which PM you want to shut down. If appropriate, use the Identify button (see Identifying a Physical Machine).
  2. In the ztC Edge Console, click Physical Machines in the left-hand navigation panel.
  3. Select the appropriate PM (node0 or node1, if it exists) and then click Work On, which changes the PM's Overall State to Maintenance Mode and the Activity state to running (in Maintenance).
  4. After the PM displays running (in Maintenance), click Shutdown.

After the PM has shut down, its activity is off (in Maintenance). You must manually restart the PM.

To shut down a PM with the power button

Related Topics

Maintenance Mode

ztC Edge Console

Managing Physical Machines

Physical Machines Page